Chemstry Analyzer

Our Chemstry Analyzer Products

We offer top-notch services based on countless years of experience.

3000 Evolution The New Semi Automatic Laboratory Anaylzer For Clinical Chemstry Tests { Compact Design }

Technical Features Operating modes :- Absorbance , End - Point , Kinetic , Fixed Time , Multistandard Differential Flow Cell :- 18 µ Typical Working volume :- 500 µ Minimum working volume :- 350 µ Carry over : <1% Intake :- Peristatic Pump with Programmable Intake Volume and Air gap setting Spectral Range :- 320 to 690 NM Filters wavelengths :- 340,405,492,505,546,578,630 nm ; 1 empty Position READING : Monochromatic, Bichromatic Reagents Blank saving :- included Measuring Range :- From -0.200 to 2.500 O.D Photometric accuracy:- ± 1% From 0 to 2.000.OD Photometric Linearity :- ± 1% From 0 to 2.000 O.D Reproductibilty : CV <1% From 0 to 2.000 O.D Results Memory : 400 Test Results ID sample :- Selectable Qc Program :- Last 30 Results , 2 Levels for 30 Selectable Tests with Levery - Jennings Plot Display :- Graphic 240 × 128 Pixel Incubator : 10 Position ; ± 0.2°C Cuvette :- Squared or Cylindrical cuvvete Printer :- Bulit - IN Graphic 24 columns Power Supply :- Auto sensing ( 80-260V ) Weight :- 11 Kg

READ MORE

RT - 9700 Semi-auto chemistry anaylzer

Technical Features • 7" color LCD , touch screen & keypad • Reagents open system supports Flow Cell and cuvette mode , Close System On request • analytical modes Include Kinetics , Fixed Time , Bichromatic end- point with or without reagent blank or sample blank , linear or non linear calibration • Real-time curve monitoring enhances the reliability of Result • Large Memory up to 75 test protocols can be programmed • powerful QC Function : westgurad Multi- Rule , Levey Jennings Plot , 2 controls Per test • Auto Power - on Self check • Additional Lamp Saving • Multiform Result Output including Patient Comprehey Report

READ MORE

Centronic photometer ANALYZER C-17

Semi automated chemistry analyzer Resolution 0.001Abs ( Display ),0.0001Abs ( Internal calculation) light source : halogen tungsten lamp wavelength : there are 5 filters inside : 340,405,500,546,620,: three more wavelengths can be added as optional . temperature control : ambient temperature ,25,30,37°c flow-cell : flow-cell interface : rs-232 bidirectional communication display : liquid crystal display print : internal printer work environment : 10°c-55°c, relative humidity≤93% weight : 7kg overall dimensions : 360mm(l)×318mm(w)×160mm (h) power supply : ac110/220v±10%,50/60hz±1hz power input :80VA

READ MORE

Semi automatic chemistry photometer Clindiag( SA-20 )

Reading cuvette : Direct Reading cuvette Incubating position : 20 incubatnon position. Photometric System : - 7 filters: 340 /405 / 492 /510 /546 /578 /620 mn and 2 more open filter opsitions ,± 2nm pass-hand . Wavelength accuracy ± 2nm. Measuring system : Measuring range 0-2.500 O.D. Photometric lineanty ±2% from 0 to 2.000 O. D . Photometric accuracy ±2% from 0 to 2.000 O. D . Drift ˂ 0.005 O.D . Carry over ≤ 1% incubator temperature control : (25⁰c , 30⁰c , 37⁰ c) Precision ±0.1⁰c . Display : Back –illuminated lcd Printer : Built- in thermal printer . Interface : RS-232 . Power supply : AC110V 60Hz /220V 50 Hz . Dimensions : 34 cm ×38 cm ×18 cm . Weigh : 8.5 kg .

READ MORE

Semi automatic chemistry photometer Mindray (Ba -88A)

Analysis Method: Endpoint , with or with out reagent blank Endpoint , with sample blank and reagent blank Kinetics , with or with out reagent blank Two –point kinetics/fixed –time ,with or with out reagent blank Absorbance Turbidimetry Linear and non-linear calibration The device is equipped with 8 filters 340nm , 405nm , 450nm ,510nm ,546nm ,578nm ,630nm and 670nm .

READ MORE

Semi automatic chemistry (Photometer 5010 V5+ )

· Semi-automated photometric system · NEW! With long lifetime LED technology · Effective temperature regulation system · Flexible cuvette concept, interchangeable flow-through or standard cuvette · Teach-in capability for reagent applications via touchscreen · Bar code reader system for an easy handling of patient data · Minimal sipping volume 250 µl · Double-secured liquid control with infrared bubble detector · Future-proof operating system can easily be upgraded Type :- Semi-automatic, single-beam filter photometer Photometric Range 0 - 3.0 A Cuvette System Micro flow cell: 32 μl, 10 mm light path interchangeable with normal standard cuvettes (macro or semi-micro, disposable or special optical glass) Temperature Control :- • Internal Peltier element, temperature variable, pre-adjusted to 25 °C, 30 °C and 37 °C • Equilibration time for aspirated reaction mixture to reach 37 °C from ambient temperature: 15 s Memory :- • General operating software can be updated by PC • Reagent-open system with capacity for up to 231 programmable methods • Data import by touchscreen or PC • Up to 50 nonlinear calibration curves with max. 20 sets of points can be stored

READ MORE

Semi automatic chemistry analyzer (MTP-88)

A large screen with a touch screen feature for ease of use. Large storage space of up to 30,000 results. The device works with all analysis methods such as (2 points, End Point, Kinetic & Polygon Method) using Halogen Lamp 6 V / 10 W and using 8 filters (340, 405, 492, 510, 546, 578, 630 & 700 nm). . The device has Quartz Flow Cell characterized as 10 mm Optical Diameter & 32 ml Volume The device has a Thermal Printer and 8 places for incubation at a temperature of 37 for ease of use. The device has 3 USB slots and an external printer connection.

READ MORE

Semi automatic chemistry MICROLAB (ARX-199 )

OPTICAL SYSTEM Principle : Absorption spectrometry Range of measurement : From -0.1 to 3.0A Normal Spectral range : Automatic via filter wheel Filters : 340, 405, 505, 546, 578, 630, 670 nm. 1 extra position Bandwidth : 10nm (±2 nm) Reading error : 2% at 2.5 A Light source :Halogen lamp Zero : Automatic Settings : Monochromatic & Bichromatic readings. Detector : Schottkey type photodiode - Silicon Peltier regulated : 25°, 30° & 37°C Programmed Accuracy : 0.2°C Flow cell of : 18 µl Removable cuvettes : Macro, Semi-micro & Micro Type : Fast Thermal Graphic Printing speed : 50 mm/sec Dots per line : 384 dots/line Paper : Thermo sensitive, 57 mm wide LCD blue LED back lit : 240 x 64 pixels. Keyboard : Tactile Soft-touch Table of tests up to 200 Table of units : up to 9 units Memory : 128 KB EEPROM

READ MORE

Semi automatic chemistry Anaylzer Microlab 300

Processing Center Optimized test environment ensures accurate results Measurement takes place in a specially designed patented flowcell Superior optical design Temperature controlled, 37°C Easy-to-train, operate and maintain Interactive and intuitive testing Built in printer Built in quality control Low maintenance required Cover designed for maintenance purposes Easy paper roll or parts replacement Low volumes Minimal water consumption 30 µL measuring volume Password protection Photometric Range 0.1 to 2.3 Absorbance Resolution 0.001 Abs.

READ MORE